Back to the list of connectors[1]

HP Insight Management Agent - Server Enterprise

Description

This connector enables hardware monitoring through the HP Insight Manager (Server Agent) which supports almost all HP ProLiant and Integrity servers on Windows and Linux, as well as Tru64 servers.

This connector supersedes:

hardware[16] hpe[17] linux[18] solaris[19] windows[20]

Target

Typical platform: HP ProLiant

Operating systems: Microsoft Windows, Linux, HP Tru64, HP OpenVMS, Out-Of-Band, Oracle Solaris

Prerequisites

Leverages: HP Insight Management Agents

Technology and protocols: SNMP

Examples

CLI

metricshub HOSTNAME -t win -c +CpMgServNT --snmp v2c --community public

metricshub.yaml

resourceGroups:
  <RESOURCE_GROUP>:
    resources:
      <HOSTNAME-ID>:
        attributes:
          host.name: <HOSTNAME> # Change with actual host name
          host.type: win
        connectors: [ +CpMgServNT ] # Optional, to load only this connector
        protocols:
          snmp:
            version: v2c # Read documentation for v1, v2c and v3
            community: public # or probably something more secure

Connector Activation Criteria

The HP Insight Management Agent - Server connector will be automatically activated, and its status will be reported as OK if all the below criteria are met:

  • An SNMP Get-Next on the OID 1.3.6.1.4.1.232.1.2.2.1.1 must return a value in the same subtree

Metrics

Type Collected Metrics Specific Attributes
cpu
  • hw.cpu.speed
  • hw.cpu.speed.limit{limit_type="max"}
  • hw.status{hw.type="cpu", state="degraded|failed|ok"}
  • hw.status{hw.type="cpu", state="predicted_failure"}
  • hw.status{hw.type="cpu", state="present"}
  • hw.parent.type
  • id
  • info
  • model
  • name
  • vendor
enclosure
  • hw.enclosure.energy
  • hw.enclosure.power
  • hw.status{hw.type="enclosure", state="present"}
  • id
  • info
  • model
  • name
  • serial_number
  • type
  • vendor
fan
  • hw.status{hw.type="fan", state="degraded|failed|ok"}
  • hw.status{hw.type="fan", state="present"}
  • hw.parent.type
  • id
  • name
  • sensor_location
power_supply
  • hw.power_supply.limit
  • hw.status{hw.type="power_supply", state="degraded|failed|ok"}
  • hw.status{hw.type="power_supply", state="present"}
  • hw.parent.type
  • id
  • info
  • name
temperature
  • hw.status{hw.type="temperature", state="degraded|failed|ok"}
  • hw.status{hw.type="temperature", state="present"}
  • hw.temperature
  • hw.temperature.limit{limit_type="high.critical"}
  • hw.temperature.limit{limit_type="high.degraded"}
  • hw.parent.type
  • id
  • name
  • sensor_location
No results.