Back to the list of connectors[1]

Fujitsu-Siemens Serverview

Description

This connector enables hardware monitoring for Fujitsu-Siemens PRIMERGY servers through the Fujitsu-Siemens Serverview Agent.

This connector is superseded by:

This connector supersedes:

enterprise[5] fujitsu[6] hardware[7] linux[8] windows[9]

Target

Typical platform: Fujitsu-Siemens PRIMERGY

Operating systems: Microsoft Windows, Linux

Prerequisites

Leverages: Fujitsu-Siemens Serveview Agent

Technology and protocols: SNMP

Examples

CLI

metricshub HOSTNAME -t win -c +ServerviewNT --snmp v2c --community public

metricshub.yaml

resourceGroups:
  <RESOURCE_GROUP>:
    resources:
      <HOSTNAME-ID>:
        attributes:
          host.name: <HOSTNAME> # Change with actual host name
          host.type: win
        connectors: [ +ServerviewNT ] # Optional, to load only this connector
        protocols:
          snmp:
            version: v2c # Read documentation for v1, v2c and v3
            community: public # or probably something more secure

Connector Activation Criteria

The Fujitsu-Siemens Serverview connector will be automatically activated, and its status will be reported as OK if all the below criteria are met:

  • An SNMP Get-Next on the OID 1.3.6.1.4.1.231.2.10.2 must return a value in the same subtree

Metrics

Type Collected Metrics Specific Attributes
cpu
  • hw.cpu.speed.limit{limit_type="max"}
  • hw.status{hw.type="cpu", state="degraded|failed|ok"}
  • hw.status{hw.type="cpu", state="present"}
  • hw.parent.type
  • id
  • info
  • model
  • name
  • vendor
enclosure
  • hw.status{hw.type="enclosure", state="open"}
  • hw.status{hw.type="enclosure", state="present"}
  • id
  • model
  • name
  • serial_number
  • type
  • vendor
fan
  • hw.fan.speed
  • hw.status{hw.type="fan", state="degraded|failed|ok"}
  • hw.status{hw.type="fan", state="present"}
  • hw.parent.id
  • hw.parent.type
  • id
  • info
  • name
  • sensor_location
memory
  • hw.errors{hw.type="memory"}
  • hw.memory.limit
  • hw.status{hw.type="memory", state="degraded|failed|ok"}
  • hw.status{hw.type="memory", state="present"}
  • hw.parent.type
  • id
  • info
  • name
  • type
power_supply
  • hw.status{hw.type="power_supply", state="degraded|failed|ok"}
  • hw.status{hw.type="power_supply", state="present"}
  • hw.parent.id
  • hw.parent.type
  • id
  • name
  • power_supply_type
temperature
  • hw.status{hw.type="temperature", state="present"}
  • hw.temperature
  • hw.temperature.limit{limit_type="high.critical"}
  • hw.temperature.limit{limit_type="high.degraded"}
  • hw.parent.id
  • hw.parent.type
  • id
  • name
  • sensor_location
voltage
  • hw.status{hw.type="voltage", state="present"}
  • hw.voltage
  • hw.voltage.limit{limit_type="high.critical"}
  • hw.voltage.limit{limit_type="low.critical"}
  • hw.parent.id
  • hw.parent.type
  • id
  • name
  • sensor_location
No results.