Description
This connector discovers the enclosure and fiber-channel ports of SAN switches as well as various environment sensors (temperatures, fans, power supplies, etc.). It relies on the WBEM technology and supports SMI-S compliant switches only.
This connector is superseded by:
- CiscoSSH[2]
- BrocadeSwitchWBEM[3]
enterprise[4] hardware[5] storage[6]
Target
Typical platform: Any SMI-S compliant SAN switch
Operating system: Storage System
Prerequisites
Leverages: SMI-S Agent provided by the switch vendor
Technology and protocols: WBEM
Examples
CLI
metricshub HOSTNAME -t storage -c +SMISSwitch --wbem -u USER
metricshub.yaml
resourceGroups:
<RESOURCE_GROUP>:
resources:
<HOSTNAME-ID>:
attributes:
host.name: <HOSTNAME> # Change with actual host name
host.type: storage
connectors: [ +SMISSwitch ] # Optional, to load only this connector
protocols:
wbem:
protocol: https
port: 5989
username: <USERNAME> # Change with actual credentials
password: <PASSWORD> # Encrypted using metricshub-encrypt
Connector Activation Criteria
The SMI-S Compliant SAN Switches connector will be automatically activated, and its status will be reported as OK if all the below criteria are met:
- The WBEM query below to the managed host succeeds:
- Namespace:
Automatic
- WQL Query:
SELECT Dedicated FROM CIM_ComputerSystem
- Result contains:
^5|;*$
(regex)
- Namespace:
- The WBEM query below to the managed host succeeds:
- Namespace:
Automatic
- WQL Query:
SELECT PortType FROM CIM_FCPort
- Result contains:
^\(14\)\|\(15\)\|\(16\)\|\(17\)\|\(18\);$
(regex)
- Namespace:
Metrics
Type | Collected Metrics | Specific Attributes |
---|---|---|
enclosure |
|
|
fan |
|
|
network |
|
|
other_device |
|
|
power_supply |
|
|
temperature |
|
|
Search Results for {{siteSearch | truncate:'50'}}