Back to the list of connectors[1]

Quantum i40/i80 (ADIC) based Tape Libraries Enterprise

Description

This connector enables hardware monitoring for i40/i80 Quantum Tape Libraries through the SNMP Agent (ADIC).

hardware[2] quantum[3] storage[4]

Target

Typical platform: Quantum i40/i80 (ADIC) Scalar Tape Library

Operating system: Storage System

Prerequisites

Leverages: Quantum SNMP Agent (ADIC-TAPE-LIBRARY-MIB)

Technology and protocols: SNMP

This connector is not available for the local host (it is applicable to remote hosts only).

Examples

CLI

metricshub HOSTNAME -t storage -c +QuantumTapeLibraryi40 --snmp v2c --community public

metricshub.yaml

resourceGroups:
  <RESOURCE_GROUP>:
    resources:
      <HOSTNAME-ID>:
        attributes:
          host.name: <HOSTNAME> # Change with actual host name
          host.type: storage
        connectors: [ +QuantumTapeLibraryi40 ] # Optional, to load only this connector
        protocols:
          snmp:
            version: v2c # Read documentation for v1, v2c and v3
            community: public # or probably something more secure

Connector Activation Criteria

The Quantum i40/i80 (ADIC) based Tape Libraries connector will be automatically activated, and its status will be reported as OK if all the below criteria are met:

  • An SNMP Get-Next on the OID 1.3.6.1.4.1.3697.1.10.10.1.6 must return a value in the same subtree

Metrics

Type Collected Metrics Specific Attributes
enclosure
  • hw.status{hw.type="enclosure", state="degraded|failed|ok"}
  • hw.status{hw.type="enclosure", state="present"}
  • bios_version
  • id
  • model
  • name
  • serial_number
  • type
  • vendor
fan
  • hw.status{hw.type="fan", state="degraded|failed|ok"}
  • hw.status{hw.type="fan", state="present"}
  • hw.parent.id
  • hw.parent.type
  • id
  • name
  • sensor_location
power_supply
  • hw.status{hw.type="power_supply", state="degraded|failed|ok"}
  • hw.status{hw.type="power_supply", state="present"}
  • hw.parent.id
  • hw.parent.type
  • id
  • name
  • power_supply_type
robotics
  • hw.status{hw.type="robotics", state="degraded|failed|ok"}
  • hw.status{hw.type="robotics", state="present"}
  • hw.parent.id
  • hw.parent.type
  • id
  • name
  • robotics_type
tape_drive
  • hw.status{hw.type="tape_drive", state="degraded|failed|ok"}
  • hw.status{hw.type="tape_drive", state="needs_cleaning"}
  • hw.status{hw.type="tape_drive", state="present"}
  • hw.tape_drive.operations{type="mount"}
  • hw.parent.id
  • hw.parent.type
  • id
  • model
  • name
  • serial_number
  • vendor