MetricsHub
MetricsHub Enterprise 1.1.00
Connectors directory[1] Full listing of connectors[2]
Lenovo ThinkSystem (IMM, XCC)
Description
This connector enables the hardware monitoring for the Lenovo ThinkSystem server through its Integrated Management Module (IMM, IMM2) or the Lenovo XClarity Controller (XCC), using SNMP.
enterprise[3] hardware[4] lenovo[5]
Target
Typical platform: Lenovo ThinkSystem[6]
Operating system: Out-Of-Band
Prerequisites
Leverages: Lenovo ThinkSystem SNMP Agent
Technology and protocols: SNMP
This connector is not available for the local host (it is applicable to remote hosts only).
Examples
CLI
metricshub HOSTNAME -t management -c +LenovoThinkSystem --snmp v2c --community public
metricshub.yaml
resourceGroups:
<RESOURCE_GROUP>:
resources:
<HOSTNAME-ID>:
attributes:
host.name: <HOSTNAME> # Change with actual host name
host.type: management
connectors: [ +LenovoThinkSystem ] # Optional, to load only this connector
protocols:
snmp:
version: v2c # Read documentation for v1, v2c and v3
community: public # or probably something more secure
Connector Activation Criteria
The Lenovo ThinkSystem (IMM, XCC) connector will be automatically activated, and its status will be reported as OK if all the below criteria are met:
- An SNMP Get-Next on the OID
1.3.6.1.4.1.19046.11.1.1.5.20.1
must return a value in the same subtree
Metrics
Type | Collected Metrics | Specific Attributes |
---|---|---|
battery |
|
|
cpu |
|
|
disk_controller |
|
|
enclosure |
|
|
fan |
|
|
led |
|
|
logical_disk |
|
|
memory |
|
|
physical_disk |
|
|
power_supply |
|
|
temperature |
|
|
voltage |
|
|