Back to the list of connectors[1]

IBM DataPower (SNMP) Enterprise

Description

This connector discovers the enclosure and the disks of IBM DataPower Appliances as well as various environment sensors (temperatures, fans, power supplies). It relies on the SNMP protocol.

Target

Typical platform: IBM DataPower

Operating system: Out-Of-Band

Prerequisites

Leverages: IBM DataPower SNMP Agent

Technology and protocols: SNMP

This connector is not available for the local host (it is applicable to remote hosts only).

Examples

CLI

metricshub HOSTNAME -t management -c +IBMDataPower --snmp v2c --community public

metricshub.yaml

resourceGroups:
  <RESOURCE_GROUP>:
    resources:
      <HOSTNAME-ID>:
        attributes:
          host.name: <HOSTNAME> # Change with actual host name
          host.type: management
        selectConnectors: [ IBMDataPower ] # Optional, to load only this connector
        protocols:
          snmp:
            version: v2c # Read documentation for v1, v2c and v3
            community: public # or probably something more secure

Connector Activation Criteria

The IBM DataPower (SNMP) connector will be automatically activated, and its status will be reported as OK if all the below criteria are met:

  • An SNMP Get-Next on the OID 1.3.6.1.4.1.14685.3.1.100.1 must return a value in the same subtree

Metrics

Type Collected Metrics Specific Attributes
enclosure
  • hw.status{hw.type="enclosure", state="present"}
  • id
  • model
  • name
  • type
  • vendor
fan
  • hw.fan.speed
  • hw.fan.speed.limit{limit_type="low.critical"}
  • hw.status{hw.type="fan", state="present"}
  • hw.parent.type
  • id
  • name
physical_disk
  • hw.status{hw.type="physical_disk", state="degraded|failed|ok"}
  • hw.status{hw.type="physical_disk", state="present"}
  • hw.parent.type
  • id
  • model
  • name
  • vendor
power_supply
  • hw.status{hw.type="power_supply", state="degraded|failed|ok"}
  • hw.status{hw.type="power_supply", state="present"}
  • hw.parent.type
  • id
  • name
temperature
  • hw.status{hw.type="temperature", state="present"}
  • hw.temperature
  • hw.temperature.limit{limit_type="high.critical"}
  • hw.temperature.limit{limit_type="high.degraded"}
  • hw.parent.type
  • id
  • name
voltage
  • hw.status{hw.type="voltage", state="present"}
  • hw.voltage
  • hw.voltage.limit{limit_type="high.degraded"}
  • hw.voltage.limit{limit_type="low.critical"}
  • hw.parent.type
  • id
  • name
No results.