Back to the list of connectors[1]

IBM BladeCenter Management Module Enterprise

Description

This connector enables hardware monitoring for IBM BladeCenter chassis through the IBM BladeCenter Management Module (SNMP-based). Needs to run remotely.

Target

Typical platform: IBM BladeCenter

Operating system: Out-Of-Band

Prerequisites

Leverages: IBM BladeCenter Management Module

Technology and protocols: SNMP

This connector is not available for the local host (it is applicable to remote hosts only).

Examples

CLI

metricshub HOSTNAME -t management -c +IBMBlade --snmp v2c --community public

metricshub.yaml

resourceGroups:
  <RESOURCE_GROUP>:
    resources:
      <HOSTNAME-ID>:
        attributes:
          host.name: <HOSTNAME> # Change with actual host name
          host.type: management
        selectConnectors: [ IBMBlade ] # Optional, to load only this connector
        protocols:
          snmp:
            version: v2c # Read documentation for v1, v2c and v3
            community: public # or probably something more secure

Connector Activation Criteria

The IBM BladeCenter Management Module connector will be automatically activated, and its status will be reported as OK if all the below criteria are met:

  • An SNMP Get-Next on the OID 1.3.6.1.4.1.2.3.51.2.2.1.1.2 must return a value in the same subtree

Metrics

Type Collected Metrics Specific Attributes
blade
  • hw.power_state{hw.type="blade", state="off|on|suspended"}
  • hw.status{hw.type="blade", state="degraded|failed|ok"}
  • hw.status{hw.type="blade", state="present"}
  • blade_name
  • hw.parent.id
  • hw.parent.type
  • id
  • info
  • model
  • name
  • serial_number
enclosure
  • hw.enclosure.energy
  • hw.enclosure.power
  • hw.status{hw.type="enclosure", state="present"}
  • id
  • info
  • model
  • name
  • serial_number
  • type
  • vendor
fan
  • hw.fan.speed_ratio
  • hw.fan.speed_ratio.limit{limit_type="low.degraded"}
  • hw.status{hw.type="fan", state="degraded|failed|ok"}
  • hw.status{hw.type="fan", state="present"}
  • hw.parent.id
  • hw.parent.type
  • id
  • name
other_device
  • hw.status{hw.type="other_device", state="degraded|failed|ok"}
  • hw.status{hw.type="other_device", state="present"}
  • device_type
  • hw.parent.type
  • id
  • info
  • name
power_supply
  • hw.status{hw.type="power_supply", state="degraded|failed|ok"}
  • hw.status{hw.type="power_supply", state="present"}
  • hw.parent.id
  • hw.parent.type
  • id
  • info
  • name
  • power_supply_type
temperature
  • hw.status{hw.type="temperature", state="degraded|failed|ok"}
  • hw.status{hw.type="temperature", state="present"}
  • hw.temperature
  • hw.temperature.limit{limit_type="high.critical"}
  • hw.temperature.limit{limit_type="high.degraded"}
  • hw.parent.id
  • hw.parent.type
  • id
  • name
voltage
  • hw.status{hw.type="voltage", state="present"}
  • hw.voltage
  • hw.voltage.limit{limit_type="high.degraded"}
  • hw.voltage.limit{limit_type="low.critical"}
  • hw.parent.id
  • hw.parent.type
  • id
  • name
  • sensor_location
No results.