Back to the list of connectors[1]

HP-UX - Smart Array RAID Enterprise

Description

This connector discovers and collects hardware data the physical disks connected to a Smart Array controller and any configured logical drive and spare drive.

This connector is superseded by:

hardware[3] hp-ux[4] hpe[5] raid[6]

Target

Typical platforms: HP 9000 HP Integrity HP SuperDome

Operating system: HP-UX

Prerequisites

Leverages: HP-UX Smart Array Configuration Utility

Technology and protocols: Command Lines

This connector requires advanced privileges on the managed host for the command below:

  • /opt/raidsa/bin/sautil

This connector therefore needs to run as root or you need to configure a privilege-escalation mechanism like sudo on the managed host to allow the monitoring account to run the command listed above.

Sample of /etc/sudoers to allow the above command to be run as root by the metricshub account:

metricshub ALL=(root) NOPASSWD: /opt/raidsa/bin/sautil

Examples

CLI

metricshub HOSTNAME -t hp -c +HPUXSAUtil --ssh -u USER --sudo-command-list /opt/raidsa/bin/sautil

metricshub.yaml

resourceGroups:
  <RESOURCE_GROUP>:
    resources:
      <HOSTNAME-ID>:
        attributes:
          host.name: <HOSTNAME> # Change with actual host name
          host.type: hp
        connectors: [ +HPUXSAUtil ] # Optional, to load only this connector
        protocols:
          ssh:
            username: <USERNAME> # Change with actual credentials
            password: <PASSWORD> # Encrypted using metricshub-encrypt
            useSudo: true
            useSudoCommands: [ "/opt/raidsa/bin/sautil" ]

Connector Activation Criteria

The HP-UX - Smart Array RAID connector will be automatically activated, and its status will be reported as OK if all the below criteria are met:

  • Operating System is HP-UX
  • The command below succeeds on the monitored host
    • Command: ls /opt/raidsa/bin/sautil
    • Output contains: sautil$ (regex)
  • The command below succeeds on the monitored host
    • Command: /bin/sh ${file::embeddedFile-1}
    • Output contains: [GgTtMm][Bb] (regex)

Metrics

Type Collected Metrics Specific Attributes
battery
  • hw.status{hw.type="battery", state="degraded|failed|ok"}
  • hw.status{hw.type="battery", state="present"}
  • hw.parent.id
  • hw.parent.type
  • id
  • info
  • name
disk_controller
  • hw.status{hw.type="disk_controller", state="present"}
  • controller_number
  • firmware_version
  • hw.parent.type
  • id
  • model
  • name
logical_disk
  • hw.logical_disk.limit
  • hw.status{hw.type="logical_disk", state="degraded|failed|ok"}
  • hw.status{hw.type="logical_disk", state="present"}
  • hw.parent.id
  • hw.parent.type
  • id
  • info
  • name
  • raid_level
physical_disk
  • hw.physical_disk.size
  • hw.status{hw.type="physical_disk", state="degraded|failed|ok"}
  • hw.status{hw.type="physical_disk", state="present"}
  • hw.parent.id
  • hw.parent.type
  • id
  • info
  • name
No results.