MetricsHub
MetricsHub Enterprise 1.0.01
Back to the list of connectors[1]
HP-UX - Smart Array RAID Enterprise
Description
This connector discovers and collects hardware data the physical disks connected to a Smart Array controller and any configured logical drive and spare drive.
This connector is superseded by:
- HPUXWBEM[2]
Target
Typical platforms: HP 9000 HP Integrity HP SuperDome
Operating system: HP-UX
Prerequisites
Leverages: HP-UX Smart Array Configuration Utility
Technology and protocols: Command Lines
This connector requires advanced privileges on the managed host for the command below:
/opt/raidsa/bin/sautil
This connector therefore needs to run as root or you need to configure a privilege-escalation mechanism like sudo
on the managed host to allow the monitoring account to run the command listed above.
Sample of /etc/sudoers to allow the above command to be run as root by the metricshub account:
metricshub ALL=(root) NOPASSWD: /opt/raidsa/bin/sautil
Examples
CLI
metricshub HOSTNAME -t hp -c +HPUXSAUtil --ssh -u USER --sudo-command-list /opt/raidsa/bin/sautil
metricshub.yaml
resourceGroups:
<RESOURCE_GROUP>:
resources:
<HOSTNAME-ID>:
attributes:
host.name: <HOSTNAME> # Change with actual host name
host.type: hp
connectors: [ +HPUXSAUtil ] # Optional, to load only this connector
protocols:
ssh:
username: <USERNAME> # Change with actual credentials
password: <PASSWORD> # Encrypted using metricshub-encrypt
useSudo: true
useSudoCommands: [ "/opt/raidsa/bin/sautil" ]
Connector Activation Criteria
The HP-UX - Smart Array RAID connector will be automatically activated, and its status will be reported as OK if all the below criteria are met:
- Operating System is HP-UX
- The command below succeeds on the monitored host
- Command:
ls /opt/raidsa/bin/sautil
- Output contains:
sautil$
(regex)
- Command:
- The command below succeeds on the monitored host
- Command:
/bin/sh ${file::embeddedFile-1}
- Output contains:
[GgTtMm][Bb]
(regex)
- Command:
Metrics
Type | Collected Metrics | Specific Attributes |
---|---|---|
battery |
|
|
disk_controller |
|
|
logical_disk |
|
|
physical_disk |
|
|