MetricsHub
MetricsHub Enterprise 1.0.02
Back to the list of connectors[1]
HP-UX - HBA
Description
This connector provides hardware status information for the fiber channel HBA cards on HP UX systems.
This connector supersedes:
enterprise[4] hardware[5] hp-ux[6] hpe[7]
Target
Typical platforms: HP 9000 HP Integrity HP SuperDome
Operating system: HP-UX
Prerequisites
Leverages: HP UX system commands (ioscan, fcmsutil)
Technology and protocols: Command Lines
This connector requires advanced privileges on the managed host for the commands below:
/usr/sbin/ioscan
/opt/fcms/bin/fcmsutil
This connector therefore needs to run as root or you need to configure a privilege-escalation mechanism like sudo
on the managed host to allow the monitoring account to run the commands listed above.
Sample of /etc/sudoers to allow the above commands to be run as root by the metricshub account:
metricshub ALL=(root) NOPASSWD: /usr/sbin/ioscan
metricshub ALL=(root) NOPASSWD: /opt/fcms/bin/fcmsutil
Examples
CLI
metricshub HOSTNAME -t hp -c +HPUXHBA --ssh -u USER --sudo-command-list /usr/sbin/ioscan,/opt/fcms/bin/fcmsutil
metricshub.yaml
resourceGroups:
<RESOURCE_GROUP>:
resources:
<HOSTNAME-ID>:
attributes:
host.name: <HOSTNAME> # Change with actual host name
host.type: hp
connectors: [ +HPUXHBA ] # Optional, to load only this connector
protocols:
ssh:
username: <USERNAME> # Change with actual credentials
password: <PASSWORD> # Encrypted using metricshub-encrypt
useSudo: true
useSudoCommands: [ "/usr/sbin/ioscan", "/opt/fcms/bin/fcmsutil" ]
Connector Activation Criteria
The HP-UX - HBA connector will be automatically activated, and its status will be reported as OK if all the below criteria are met:
- The command below succeeds on the monitored host
- Command:
/usr/sbin/ioscan -fnC fc
- Output contains:
/dev/
(regex)
- Command:
Metrics
Type | Collected Metrics | Specific Attributes |
---|---|---|
network |
|
|