Back to the list of connectors[1]

Fujitsu-Siemens Management Blade (FSC BX Blade Servers) Enterprise

Description

This connector enables hardware monitoring through the Fujitsu-Siemens Management Blade SNMP Agent which supports the Fujitsu-Siemens Blade servers (BX300, BX600, etc.). Needs to run remotely.

Target

Typical platform: Fujitsu-Siemens BX Blade

Operating system: Out-Of-Band

Prerequisites

Leverages: Fujitsu-Siemens Management Blade

Technology and protocols: SNMP

This connector is not available for the local host (it is applicable to remote hosts only).

Examples

CLI

metricshub HOSTNAME -t management -c +FujitsuSiemensBlade --snmp v2c --community public

metricshub.yaml

resourceGroups:
  <RESOURCE_GROUP>:
    resources:
      <HOSTNAME-ID>:
        attributes:
          host.name: <HOSTNAME> # Change with actual host name
          host.type: management
        selectConnectors: [ FujitsuSiemensBlade ] # Optional, to load only this connector
        protocols:
          snmp:
            version: v2c # Read documentation for v1, v2c and v3
            community: public # or probably something more secure

Connector Activation Criteria

The Fujitsu-Siemens Management Blade (FSC BX Blade Servers) connector will be automatically activated, and its status will be reported as OK if all the below criteria are met:

  • An SNMP Get on the OID 1.3.6.1.4.1.7244.1.1.1.1.12.1.0 must return a value that matches with the 3 (regular expression)

Metrics

Type Collected Metrics Specific Attributes
blade
  • hw.status{hw.type="blade", state="degraded|failed|ok"}
  • hw.status{hw.type="blade", state="present"}
  • hw.parent.id
  • hw.parent.type
  • id
  • model
  • name
enclosure
  • hw.status{hw.type="enclosure", state="present"}
  • id
  • model
  • name
  • type
  • vendor
fan
  • hw.fan.speed
  • hw.status{hw.type="fan", state="degraded|failed|ok"}
  • hw.status{hw.type="fan", state="present"}
  • hw.parent.id
  • hw.parent.type
  • id
  • name
  • sensor_location
power_supply
  • hw.status{hw.type="power_supply", state="degraded|failed|ok"}
  • hw.status{hw.type="power_supply", state="present"}
  • hw.parent.id
  • hw.parent.type
  • id
  • name
  • power_supply_type
temperature
  • hw.status{hw.type="temperature", state="present"}
  • hw.temperature
  • hw.temperature.limit{limit_type="high.critical"}
  • hw.temperature.limit{limit_type="high.degraded"}
  • hw.parent.id
  • hw.parent.type
  • id
  • name
  • sensor_location
No results.