Skip to main content

Lenovo IMM Event Monitoring (SNMP)

Description​

This connector enables hardware monitoring for IBM xSeries through Lenovo's IMM management card. It supplements the active monitoring of the Lenovo IMM connector by parsing the Event Log. This allows older IBM xSeries systems to be fully monitored via their IMM.

hardware lenovo

Enterprise Connector

This connector requires the Enterprise edition of MetricsHub.

Target​

Typical platform: IBM xSeries

Operating system: Out-Of-Band

Prerequisites​

Leverages: Lenovo IMM's SNMP Service

Technology and protocols: SNMP

Examples​

CLI​

metricshub HOSTNAME -t oob -c +LenovoIMMEventTable --snmp v2c --community public

metricshub.yaml​

resourceGroups:
<RESOURCE_GROUP>:
resources:
<HOSTNAME-ID>:
attributes:
host.name: <HOSTNAME> # Change with actual host name
host.type: oob
connectors: [ +LenovoIMMEventTable ] # Optional, to load only this connector
protocols:
snmp:
version: v2c # Read documentation for v1, v2c and v3
community: public # or probably something more secure

Connector Activation Criteria​

The Lenovo IMM Event Monitoring (SNMP) connector will be automatically activated, and its status will be reported as OK if all the below criteria are met:

  • An SNMP GetNext on the OID 1.3.6.1.4.1.2.3.51.3.2.1.1.1 must return a non-empty value

Metrics​

TypeCollected MetricsSpecific Attributes
other_devicehw.status{hw.type="other_device", state="degraded|failed|ok"}
hw.status{hw.type="other_device", state="present"}
hw.parent.type
id
name